Shopping Cart 0
$0.00

DAHUA PFM920I-5EUN UTP CAT5e Cable

In stock
SKU
PFM920I-5EUN
$1,000,000.00

>305 m (1000 ft)/carton UTP CAT5e, power over Ethernet, compatible with one cable

> High-purity oxygen-free copper conductor

> Customized PVC outer sheath; CE CPR Eca flame retardant classcertified

> 10-year warranty

>305 m (1000 ft)/carton UTP CAT5e, power over Ethernet, compatible with one cable

> High-purity oxygen-free copper conductor

> Customized PVC outer sheath; CE CPR Eca flame retardant classcertified

> 10-year warranty

Conductor

Material

Oxygen free copper (99.97% purity)

Diameter

0.45 mm ± 0.01 mm

Insulation

Material

HDPE

Min. Average Thickness

0.18 mm

Diameter

0.81mm±0.1mm

Color (4 Pairs)

Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown

Rip Cord

Material

Polyester

Specification

500D

Sheath

Material

PVC

Min. Average Thickness

0.5 mm

Diameter

4.7 mm ± 0.3 mm

Color

White

Electrical

Max. DC Resistance of a Single Conductor

12Ω/100 m

Min. Insulation Resistance

5000MΩ·km

Max. DC Resistance Unbalance

2% (pair intra), 4% (pairs inter)

Dielectric Strength

No breakdown with 1KV DC for 1 min

Transmission

Characteristic Impedance

100 ± 15Ω

Near End Cross Talk

≥35.30 dB/100 m@100 MHz

Max. Attenuation

24.2 dB/100 m@100 MHz

Return Loss

≥20.1 dB/100 m@100 MHz

Mechanical

Tensile Strength

Sheath≥13.5 MPa, insulation≥16 MPa

Elongation at Break

Sheath≥150%, insulation≥300%

Installation Bending Radius

>8 times of outer cable diameter

Conductor Elongation at Break

≥10%

Environmental

Shrinkage of Insulation

≤5%

Color Migration Resistance of Insulation

No migration

Sheath Tensile Strength and Elongation at Break after Aging

≥12.5 MPa, ≥100%

Low Temperature Bending Test

No cracking after the test

Heat Shock Test

No cracking after the test

Operating Temperature

–20°C to +60°C (–4°F to 140°F)

Installation Temperature

0°C to +50°C (32°F to 122°F)

Storage Temperature and Humidity

–10°C to +40°C (14°F to 104°F), <60% (RH)

Security

Vertical Fire Propagation Test

Comply with IEC 60332-1-2

Packaging

Cable Length

305.0 m (1000.66 ft) ± 1.5 m (4.92 ft)

Inner Carton Dimensions

364.0 mm × 364.0 mm × 216.0 mm

(14.33" × 14.33" × 8.50") (L × W × H)

Packaging Method

305.0 m (1000.66 ft) a carton, 45 pcs/pallet


Net Weight

≥7.0 kg (15.43 lb)

Gross Weight

≥8.0 kg (17.64 lb)

Compliance

Executive Standards

Q/DXJ 067-2019, EN50575-2014

Certification

Certification

CPR Eca

Transmission Characteristics

(100 m at 20°C) (328.08 ft at 68°F)

Frequency (MHz)

Phase delay ≤ ns

IL ≤ dB

TCL≥ dB﹡

EL TCTL

≥ dB﹡

NEXT ≥ dB

PS NEXT ≥ dB

1

n/s

n/s

50.0

35.0

n/s

n/s

4

552.0

4.5

44.0

23.0

56.3

53.3

8

547.0

6.4

41.0

16.9

51.8

48.8

10

545.0

7.2

40.0

15.0

50.3

47.3

16

543.0

9.0

38.0

10.9

47.2

44.2

20

542.0

10.2

37.0

9.0

45.8

42.8

25

541.0

11.4

36.0

7.0

44.3

41.3

30﹡

540.6

12.6

35.2

5.5

43.1

40.1

31.25

540.0

12.9

35.1

n/s

42.9

39.9

62.5

539.0

18.7

32.0

n/s

38.4

35.4

100

538.0

24.2

30.0

n/s

35.3

32.3

Frequency (MHz)

EL FEXT ≥ dB

PS EL FEXT ≥ dB

RL ≥ dB

Delay skew≤ ns

Zc(Ω)

1

n/s

n/s

n/s

n/s

n/s

4

52.0

49.0

23.0

45.0

100±15

8

45.9

42.9

24.5

10

44.0

41.0

25.0

16

39.9

36.9

25.0

20

38.0

35.0

25.0

25

36.0

33.0

24.3

30﹡

34.5

31.5

23.8

31.25

34.1

31.1

23.6

62.5

28.1

25.1

21.5

100

24.0

21.0

20.1

Note:

Executive standard for the above parameters: Q/DXJ 067-2019"n/s"=Not Specified

"﹡"=Unless otherwise customer stated the test results default to not shown in test report but comply with standard

Write Your Own Review
You're reviewing:DAHUA PFM920I-5EUN UTP CAT5e Cable
Your Rating
Brand Description
History Color sit amet, consectetur adipiscing elit. In gravida pellentesque ligula, vel eleifend turpis blandit vel. Nam quis lorem ut mi mattis ullamcorper ac quis dui. Vestibulum et scelerisque ante, eu sodales mi. Nunc tincidunt tempus varius. Integer ante dolor, suscipit non faucibus a, scelerisque vitae sapien.